Customization: | Available |
---|---|
After-sales Service: | 2 Year |
Warranty: | 2 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Working condition | |||||||||||||||||
Flow rate | 1t/h | Feeding temperature | 35ºC | Steam pressure | 0.5~0.6MPa | ||||||||||||
Design requirment | |||||||||||||||||
Sterilizing temperature | 110~135ºC | Sterilizing time | 15S | Outlet temperature | 88ºC | ||||||||||||
Main Technology Parameter | |||||||||||||||||
ITEM | Technology Parameter | ITEM | Technology Parameter | ||||||||||||||
Model | HTST-1000 | Power | 6KW | ||||||||||||||
Heating area | 15M2 | Material inlet&outlet pipe diameter |
¢32 | ||||||||||||||
Plate material | SUS316L | Cooling water inlet&outlet pipe diameter |
¢38 | ||||||||||||||
Sterilizing temp. | Auto control,auto record | Cooling water consumption | 2t/h | ||||||||||||||
reflux valve work status | high tem. Alarming, low tem.backflow(automatic) |
Temperature control precision | ±1ºC | ||||||||||||||
Air pressure | 0.6Mpa | Air consumption | 0.045M3/min | ||||||||||||||
Steam consumption | 110Kg/h | Pure water consumption | 2t/h (for cleaning use) | ||||||||||||||
Machine weight | 1400Kg | Machine size | 2000(L)×2000(W)×1800(H)MM | ||||||||||||||
Main Configuration List | |||||||||||||||||
No. | Parts Name | Model/Specification | Qty | Brand | Mark | ||||||||||||
1 | Plate heat exchanger | BR16-UHT-1T | 1 | SHANGHAI | |||||||||||||
2 | PENRUQI | 1 | SHANGHAI | ||||||||||||||
3 | balance tank | 120L | 1 | SHANGHAI | |||||||||||||
4 | Hot water tank | 60L | 1 | SHANGHAI | |||||||||||||
5 | centrifugal beverage pump | 3t 36m | 1 | SHANGHAI | |||||||||||||
6 | hot water pump | CDL | 1 | NANFANG | |||||||||||||
7 | Two pneumatic valve spool | ¢38 | 1 | ALFA LAVAL | SWEDEN | ||||||||||||
8 | butterfly valve | ¢38 | 4 | YUANAN | SHANGHAI | ||||||||||||
9 | Hot water ball valve | ¢38 | 3 | SHANGHAI | |||||||||||||
10 | Steam system | SPIRAX | |||||||||||||||
Steam reducing valve | 1 | SPIRAX | UK | ||||||||||||||
steam regulating valve | 1 | SPIRAX | UK | ||||||||||||||
Steam plunger valve | 1 | SPIRAX | UK | ||||||||||||||
Steam filter | 1 | SPIRAX | UK | ||||||||||||||
11 | Electrical control cabinet | 304 | 1 | SHANGHAI | |||||||||||||
temperature controller | PXR9 | 2 | FUJISOKU | ||||||||||||||
electrical element | 1 | SCHNEIDER | FRANCE | ||||||||||||||
temperature recorder | 1 | JAPAN | |||||||||||||||
12 | temperature sensor | Pt100 | 4 | JUMO | GERMANY | ||||||||||||
13 | Outlet temperature regulator | 1 | FUYANG | ||||||||||||||
14 | Frame, pipes | 304 | 1 | SHANGHAI |